Crouzet · Timers and Control Relays
Crouzet Control Relay Series
DIN rail control relays for phase, voltage, current, frequency, level and speed monitoring.
Technical Documents
Key Features
- Phase, voltage, current, frequency, liquid level and speed monitoring options
- Protection of loads such as AC motors, HVAC systems, pumps and conveyors
- Models for three-phase and single-phase networks
- True RMS measurement (depending on model)
- Selectable memory (latching) function (depending on model)
- LED status indicator
- DIN rail mounting; housing widths of 17.5 mm, 22.5 mm and 35 mm
Phase Control
| Series No. | Type | Function | Measuring Range | Supply | Output | Width |
|---|---|---|---|---|---|---|
| 84 873 023 | MWU | Phase sequence / phase loss / undervoltage | 183–528 V AC | 3 × 208–480 V AC | 1 changeover contact, 8 A | 17.5 mm |
| 84 873 024 | MWA | Phase sequence / phase loss / asymmetry | 183–528 V AC | 3 × 208–480 V AC | 1 changeover contact, 8 A | 17.5 mm |
| 84 873 025 | MWUA | Phase sequence / phase loss / asymmetry / overvoltage and undervoltage (window mode) | 183–528 V AC | 3 × 208–480 V AC | 1 changeover contact, 8 A | 17.5 mm |
| 84 873 026 | HWUA | Phase sequence / phase loss / asymmetry / independently adjustable overvoltage and undervoltage | 194–528 V AC | 3 × 220–480 V AC | 1 changeover contact, 8 A | 35 mm |
| 84 873 029 | MWS | Phase sequence / phase loss | 183–528 V AC | 3 × 208–480 V AC | 1 changeover contact, 8 A | 17.5 mm |
| 84 873 220 | H3US | Phase-to-phase overvoltage and undervoltage / phase loss | 194–528 V AC | 3 × 220–480 V AC | 2 changeover contacts, 6 A | 35 mm |
| 84 873 221 | H3USN | Phase-to-neutral overvoltage and undervoltage / neutral loss / phase loss | 96–332 V AC | 3 × 120–277 V AC | 2 changeover contacts, 5 A | 35 mm |
Voltage Control
| Series No. | Type | Function | Measuring Range | Supply | Output | Width |
|---|---|---|---|---|---|---|
| 84 872 035 | EUH | Overvoltage or undervoltage; selectable memory function | 15–600 V AC/DC | 24–240 V AC/DC | 1 changeover contact, 5 A | 22.5 mm |
| 84 872 120 | HUL | Overvoltage or undervoltage; selectable memory function | 0.2–60 V AC/DC | 24–240 V AC/DC | 2 changeover contacts, 5 A | 35 mm |
| 84 872 130 | HUH | Overvoltage or undervoltage; selectable memory function | 15–600 V AC/DC | 24–240 V AC/DC | 2 changeover contacts, 5 A | 35 mm |
| 84 872 140 | MUS12 | Overvoltage or undervoltage; selectable memory function | 9–15 V DC | 12 V DC | 1 changeover contact, 5 A | 17.5 mm |
| 84 872 141 | MUS80 | Overvoltage or undervoltage; selectable memory function | 20–80 V AC/DC | 24–48 V AC/DC | 1 changeover contact, 5 A | 17.5 mm |
| 84 872 142 | MUS260 | Overvoltage or undervoltage; selectable memory function | 65–260 V AC/DC | 110–240 V AC/DC | 1 changeover contact, 5 A | 17.5 mm |
| 84 872 151 | MUSF80 | Overvoltage and undervoltage (window mode) | 20–80 V AC/DC | 24–48 V AC/DC | 1 changeover contact, 5 A | 17.5 mm |
| 84 872 152 | MUSF260 | Overvoltage and undervoltage (window mode) | 65–260 V AC/DC | 110–240 V AC/DC | 1 changeover contact, 5 A | 17.5 mm |
Current Control
| Series No. | Type | Function | Measuring Range | Supply | Output | Width |
|---|---|---|---|---|---|---|
| 84 871 025 | EIL | Overcurrent or undercurrent; selectable memory function | 2–500 mA | 24–240 V AC/DC | 1 changeover contact, 5 A | 22.5 mm |
| 84 871 035 | EIH | Overcurrent or undercurrent; selectable memory function | 0.1–10 A | 24–240 V AC/DC | 1 changeover contact, 5 A | 22.5 mm |
| 84 871 120 | HIL | Overcurrent or undercurrent; selectable memory function | 2–500 mA | 24–240 V AC/DC | 2 changeover contacts, 5 A | 35 mm |
| 84 871 122 | MIC | Overcurrent and undercurrent; built-in current transformer | 2–20 A | 24–240 V AC/DC | 1 changeover contact, 10 A | 17.5 mm |
| 84 871 130 | HIH | Overcurrent or undercurrent; selectable memory function | 0.1–10 A | 24–240 V AC/DC | 2 changeover contacts, 5 A | 35 mm |
Frequency Control
| Series No. | Type | Function | Measuring Range | Supply | Output | Width |
|---|---|---|---|---|---|---|
| 84 872 501 | HHZ | Independently adjustable over- and underfrequency; selectable memory function | 40–70 Hz | 120–277 V AC | 2 changeover contacts, 5 A | 35 mm |
Level Control
| Series No. | Type | Function | Sensitivity Range | Supply | Output | Width |
|---|---|---|---|---|---|---|
| 84 870 100 | ENR | Filling (UP) or emptying (DOWN) monitoring | 5–100 kΩ | 24–240 V AC/DC | 1 changeover contact, 8 A | 17.5 mm |
| 84 870 110 | ENRM | Filling (UP) or emptying (DOWN) monitoring | 250 Ω – 1 MΩ | 24–240 V AC/DC | 1 changeover contact, 8 A | 17.5 mm |
| 84 870 700 | HNM | Filling (UP) or emptying (DOWN) monitoring | 250 Ω – 1 MΩ | 24–240 V AC/DC | 2 changeover contacts, 8 A | 35 mm |
Speed Control
| Series No. | Type | Function | Time Between Pulses | Supply | Output | Width |
|---|---|---|---|---|---|---|
| 84 874 320 | HSV | Overspeed, underspeed, operating speed and standstill monitoring; selectable memory function | 0.05 s – 10 min | 24–240 V AC/DC | 1 changeover contact, 5 A | 35 mm |