Crouzet · Timers and Control Relays

Crouzet Control Relay Series

DIN rail control relays for phase, voltage, current, frequency, level and speed monitoring.

Key Features

Phase Control
Series No.TypeFunctionMeasuring RangeSupplyOutputWidth
84 873 023MWUPhase sequence / phase loss / undervoltage183–528 V AC3 × 208–480 V AC1 changeover contact, 8 A17.5 mm
84 873 024MWAPhase sequence / phase loss / asymmetry183–528 V AC3 × 208–480 V AC1 changeover contact, 8 A17.5 mm
84 873 025MWUAPhase sequence / phase loss / asymmetry / overvoltage and undervoltage (window mode)183–528 V AC3 × 208–480 V AC1 changeover contact, 8 A17.5 mm
84 873 026HWUAPhase sequence / phase loss / asymmetry / independently adjustable overvoltage and undervoltage194–528 V AC3 × 220–480 V AC1 changeover contact, 8 A35 mm
84 873 029MWSPhase sequence / phase loss183–528 V AC3 × 208–480 V AC1 changeover contact, 8 A17.5 mm
84 873 220H3USPhase-to-phase overvoltage and undervoltage / phase loss194–528 V AC3 × 220–480 V AC2 changeover contacts, 6 A35 mm
84 873 221H3USNPhase-to-neutral overvoltage and undervoltage / neutral loss / phase loss96–332 V AC3 × 120–277 V AC2 changeover contacts, 5 A35 mm
Voltage Control
Series No.TypeFunctionMeasuring RangeSupplyOutputWidth
84 872 035EUHOvervoltage or undervoltage; selectable memory function15–600 V AC/DC24–240 V AC/DC1 changeover contact, 5 A22.5 mm
84 872 120HULOvervoltage or undervoltage; selectable memory function0.2–60 V AC/DC24–240 V AC/DC2 changeover contacts, 5 A35 mm
84 872 130HUHOvervoltage or undervoltage; selectable memory function15–600 V AC/DC24–240 V AC/DC2 changeover contacts, 5 A35 mm
84 872 140MUS12Overvoltage or undervoltage; selectable memory function9–15 V DC12 V DC1 changeover contact, 5 A17.5 mm
84 872 141MUS80Overvoltage or undervoltage; selectable memory function20–80 V AC/DC24–48 V AC/DC1 changeover contact, 5 A17.5 mm
84 872 142MUS260Overvoltage or undervoltage; selectable memory function65–260 V AC/DC110–240 V AC/DC1 changeover contact, 5 A17.5 mm
84 872 151MUSF80Overvoltage and undervoltage (window mode)20–80 V AC/DC24–48 V AC/DC1 changeover contact, 5 A17.5 mm
84 872 152MUSF260Overvoltage and undervoltage (window mode)65–260 V AC/DC110–240 V AC/DC1 changeover contact, 5 A17.5 mm
Current Control
Series No.TypeFunctionMeasuring RangeSupplyOutputWidth
84 871 025EILOvercurrent or undercurrent; selectable memory function2–500 mA24–240 V AC/DC1 changeover contact, 5 A22.5 mm
84 871 035EIHOvercurrent or undercurrent; selectable memory function0.1–10 A24–240 V AC/DC1 changeover contact, 5 A22.5 mm
84 871 120HILOvercurrent or undercurrent; selectable memory function2–500 mA24–240 V AC/DC2 changeover contacts, 5 A35 mm
84 871 122MICOvercurrent and undercurrent; built-in current transformer2–20 A24–240 V AC/DC1 changeover contact, 10 A17.5 mm
84 871 130HIHOvercurrent or undercurrent; selectable memory function0.1–10 A24–240 V AC/DC2 changeover contacts, 5 A35 mm
Frequency Control
Series No.TypeFunctionMeasuring RangeSupplyOutputWidth
84 872 501HHZIndependently adjustable over- and underfrequency; selectable memory function40–70 Hz120–277 V AC2 changeover contacts, 5 A35 mm
Level Control
Series No.TypeFunctionSensitivity RangeSupplyOutputWidth
84 870 100ENRFilling (UP) or emptying (DOWN) monitoring5–100 kΩ24–240 V AC/DC1 changeover contact, 8 A17.5 mm
84 870 110ENRMFilling (UP) or emptying (DOWN) monitoring250 Ω – 1 MΩ24–240 V AC/DC1 changeover contact, 8 A17.5 mm
84 870 700HNMFilling (UP) or emptying (DOWN) monitoring250 Ω – 1 MΩ24–240 V AC/DC2 changeover contacts, 8 A35 mm
Speed Control
Series No.TypeFunctionTime Between PulsesSupplyOutputWidth
84 874 320HSVOverspeed, underspeed, operating speed and standstill monitoring; selectable memory function0.05 s – 10 min24–240 V AC/DC1 changeover contact, 5 A35 mm